<LOGO>
FM Transmitter Measurement Report
Created: 2026-05-02 23-16-59
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 4/5, 43 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 4.7 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
13 kHz 69 kHz 7233 0,5668
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,1 dBr 5,36 dBr 6,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 69 kHz MIN: 13 kHz % above 76 kHz: 0,5668 Acquired: 2026/05/02 23.15.54 Total samples: 7233 Equivalent time: 0:06:01 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 6,1 dBr MIN: 4,1 dBr AVE: 5,36 dBr % above 12,2 dBr: 0,0 Last value: 5,3 dBr (2026/05/02 23.15.54) 23.02 23.04 23.06 23.08 23.10 23.12 23.14 0 2 4 6 Pm [dBr]